Utility-Scale Solar Thermal (IEC 62446-3) & 3D LiDAR Mapping
Single-pass 1280×1024 radiometric thermal and co-registered 3D LiDAR capture for utility-scale and commercial solar farms across SEQ and Northern NSW.
IEC TS 62446-3. ΔT normalised to 1,000 W/m².
Separate genuine electrical faults from 3D shading, tracker tilt and terrain issues in one pass
Flying 2D thermal inspections and 3D site surveys separately doubles site access coordination and leaves thermal and terrain datasets disconnected.
Uncalibrated thermal flights trigger false work orders when plane-of-array irradiance drops or wind cools modules mid-capture.
Solar O&M and asset teams need CMMS-ready CSV anomaly schedules and geolocated KML pins backed by 3D shading and drainage surfaces, not folders of raw JPEGs.
What lands in your inbox.
Delivered in agreed coordinate systems and formats.
- IEC TS 62446-3 thermal inspection PDF report with paired thermal/visual thumbnails and normalised delta-T calloutsPDF
- CMMS-ready anomaly schedule and geolocated fault pin dropsCSV / KML / SHP
- Co-registered classified 3D LiDAR point cloud and bare-earth DEMLAS / LAZ / DEM
- Perimeter vegetation shading and canopy encroachment layersLAS / DSM / SHP
- Tracker row alignment, trench scouring and surface drainage contoursDXF / SHP
- Checkpoint accuracy report and field plane-of-array irradiance/wind logPDF
Target turnaround of about 48 hours for standard deliverables (point cloud and DEM) on smaller sites, counted from end of capture. Site dependent, not guaranteed.
Every project is scoped first. You then get a written fixed-price quote for the agreed scope, based on site size, location, access and deliverables, before any work starts.
Questions, answered.
Capturing 1280×1024 radiometric thermal (4× the pixel density of standard 640×512 sensors) and 3D LiDAR simultaneously means every thermal anomaly is co-registered with the 3D point cloud in the same coordinate system (MGA2020/AHD). Your O&M team can immediately verify whether a hot cell, diode or string is an internal electrical defect or caused by perimeter tree shading, tracker row tilt or trench erosion—from one site mobilisation.
We capture radiometric thermal data at a minimum 600 W/m² plane-of-array (POA) irradiance logged continuously on site with a tilted pyranometer matching the array angle, wind speed under 4 m/s, ambient temperature swing within 5°C, and camera angle within 10° of perpendicular to the module plane. Every delta-T reading is normalised to 1,000 W/m² reference irradiance and classified into <2 K (thermal noise, filtered out), 2–10 K (minor / tracked anomaly), and >10 K (serious anomaly / maintenance work order required).
Alongside routine annual O&M inspections, single-pass capture is designed for high-stakes off-cycle triggers: (1) post-hail and severe storm damage assessments, (2) EPC commissioning and pre-Defect Liability Period (DLP) expiry sign-offs, (3) unexplained yield underperformance investigations, and (4) module manufacturer warranty claim evidence.
You receive a co-registered 3-part package: (1) an IEC TS 62446-3 PDF report with paired thermal/visual thumbnails, environmental logs and normalised delta-T callouts, (2) a CSV fault schedule formatted for direct import into your CMMS or maintenance platform, and (3) geolocated KML/SHP fault pins co-registered with classified LAS/LAZ point clouds, GeoTIFF DEMs and DXF drainage/shading contours.
The classified 3D LiDAR point cloud maps bare-earth terrain under and around the tables, identifying stormwater scouring along cable trenches, ponding zones, tracker post settlement and exact perimeter canopy heights that cast morning or afternoon shadows across strings.
Target vertical accuracy around 3 cm RMSE on open, hard ground with ground control; vegetation, terrain and site conditions affect results. Each project includes an accuracy report against check points.
Target turnaround of about 48 hours for standard deliverables (point cloud and DEM) on smaller sites, counted from end of capture. Site dependent, not guaranteed. Combined IEC TS 62446-3 thermal and LiDAR reporting timelines are confirmed in the written quote.
We're based in Palmwoods on the Sunshine Coast and cover South East Queensland and Northern NSW. Other regions are by arrangement.
Discuss your project
Tell us about your site. Enquiry only, no obligation and no payment.